2000W 12V Pure Sine Wave Inverter Charger w/ LCD Display
- Do not over-torque or over-tighten the terminals. This could potentially damage the unit.
- Be careful of the positive and negative poles. Reversing the poles might cause permanent damage to the inverter. It will surely blow the internal fuse.
- Avoid switching on the inverter with the load (electronic devices) already switched on. This may trigger an overload since some electronic devices have an initial high power surge to start.
- When switching off the inverter, turn off the electronic devices first. Although the inverter is off, the capacitors will still have a charge, so the DC and AC terminals must be disconnected if altering the circuitry.
|
2000W 12V Inverter Charger 1 x
|
Battery Temperature Sensor 1 x
|
|
Inverter Wired Remote Control 1 x
|
|
Inverter |
|
|---|---|
| Continuous Power | 2000W |
| AC Output Voltage Range | 100~120VAC configurable, 5V interval |
| DC Input Voltage Range | 10~16 VDC |
|
Nominal Efficiency
|
>90% Peak |
|
Surge Power (1 second)
|
6000W |
|
Output Frequency (Nominal)
|
50/60 Hz |
|
Output Waveform
|
Pure Sine Wave |
|
No Load Power Consumption
|
Normal:<20W; Power Saving:<15W |
| Charger Specifications | |
| Output Current | 5-65A configurable, 5A intervals |
| Nominal Input Voltage | 120VAC |
| Input Frenquency Range | 40Hz - 70Hz |
| Optimal Efficiency | <85% |
| Surge Power (1 second) | 6000W |
| Output Frequency (Nominal) | 50/60 Hz |
| Output Waveform | Pure Sine Wave |
| No Load Power Consumption | Normal:<20W; Power Saving:<15W |
| Input Voltage Range | 90-138 VAC |
| Input Wave Form | Sine Wave (Utility or Generator) |
| Transferswitch Specifications | |
|
Transfer Time
|
~ 10ms |
|
Transfer Rating
|
30A Automatic Transfer Switch |
| General Specification | |
|
Battery Types
|
GEL, AGM, SLA, FLD, CAL, LI, USER |
|
Noise
|
<50dB |
|
Operating Temperature
|
0 ~ 40°C / 32 ~ 104°F |
|
Storage Temperature
|
-30 ~ 70°C / -22 ~ 158°F |
|
Dimensions
|
20.1 x 11.2 x 7.6 in / 510 x 285 x 193 mm |
|
Weight
|
51.1 lbs / 23.2 Kg |
|
Humidity
|
0% ~ 95% |
|
No Load Power Consumption
|
Normal:<20W; Power Saving:<15W |
|
Input Voltage Range
|
90-138 VAC |
|
Input Wave Form
|
Sine Wave (Utility or Generator) |
| Warranty Information | |
|
Inverters
|
1-year material and workmanship warranty |
|
Accessories
|
1-year material warranty |
Note: The DC-DC Temperature Sensor cannot use with Lithium batteries.
Inverters will be rated by a wattage value, telling you how many watts they can run at one time. For example, imagine you had a 500 Watt Fridge and 800 Watt Air Conditioning. These two items would be 1300 Watts and would require an inverter with a higher wattage than 1300W. Renogy 2000W and 3000W inverter will meet your power needs.
2. Check your battery voltage.
The DC voltage rating on the inverter will tell you what battery bank it is compatible with. For example, a 12V battery bank will require an inverter that is compatible with 12V DC input.
3. Size your installation spaces.
What area or space will you set your inverter? Make sure the inverter will fit in the space you have in mind with enough room around it for proper ventilation and no fire hazards.
4. Remote operation is important.
Renogy pure sine inverters come with convenient remote control and DC HOME APP options so that you can operate the unit from afar.
Pure sine wave inverters are a bigger investment, but much more versatile.
a) Output voltage waveform is a pure sine wave with very low harmonic distortion and clean power like utility-supplied electricity.
b) Inductive loads like microwave ovens and motors run faster, quieter, and cooler.
c) Reduces audible and electrical noise in fans, fluorescent lights, audio amplifiers, TV, Game consoles, Fax, and answering machines.
d) Prevents crashes in computers, weird print out, and glitches and noise in monitors.
Original: $595.99
-70%$595.99
$178.80Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
- Do not over-torque or over-tighten the terminals. This could potentially damage the unit.
- Be careful of the positive and negative poles. Reversing the poles might cause permanent damage to the inverter. It will surely blow the internal fuse.
- Avoid switching on the inverter with the load (electronic devices) already switched on. This may trigger an overload since some electronic devices have an initial high power surge to start.
- When switching off the inverter, turn off the electronic devices first. Although the inverter is off, the capacitors will still have a charge, so the DC and AC terminals must be disconnected if altering the circuitry.
|
2000W 12V Inverter Charger 1 x
|
Battery Temperature Sensor 1 x
|
|
Inverter Wired Remote Control 1 x
|
|
Inverter |
|
|---|---|
| Continuous Power | 2000W |
| AC Output Voltage Range | 100~120VAC configurable, 5V interval |
| DC Input Voltage Range | 10~16 VDC |
|
Nominal Efficiency
|
>90% Peak |
|
Surge Power (1 second)
|
6000W |
|
Output Frequency (Nominal)
|
50/60 Hz |
|
Output Waveform
|
Pure Sine Wave |
|
No Load Power Consumption
|
Normal:<20W; Power Saving:<15W |
| Charger Specifications | |
| Output Current | 5-65A configurable, 5A intervals |
| Nominal Input Voltage | 120VAC |
| Input Frenquency Range | 40Hz - 70Hz |
| Optimal Efficiency | <85% |
| Surge Power (1 second) | 6000W |
| Output Frequency (Nominal) | 50/60 Hz |
| Output Waveform | Pure Sine Wave |
| No Load Power Consumption | Normal:<20W; Power Saving:<15W |
| Input Voltage Range | 90-138 VAC |
| Input Wave Form | Sine Wave (Utility or Generator) |
| Transferswitch Specifications | |
|
Transfer Time
|
~ 10ms |
|
Transfer Rating
|
30A Automatic Transfer Switch |
| General Specification | |
|
Battery Types
|
GEL, AGM, SLA, FLD, CAL, LI, USER |
|
Noise
|
<50dB |
|
Operating Temperature
|
0 ~ 40°C / 32 ~ 104°F |
|
Storage Temperature
|
-30 ~ 70°C / -22 ~ 158°F |
|
Dimensions
|
20.1 x 11.2 x 7.6 in / 510 x 285 x 193 mm |
|
Weight
|
51.1 lbs / 23.2 Kg |
|
Humidity
|
0% ~ 95% |
|
No Load Power Consumption
|
Normal:<20W; Power Saving:<15W |
|
Input Voltage Range
|
90-138 VAC |
|
Input Wave Form
|
Sine Wave (Utility or Generator) |
| Warranty Information | |
|
Inverters
|
1-year material and workmanship warranty |
|
Accessories
|
1-year material warranty |
Note: The DC-DC Temperature Sensor cannot use with Lithium batteries.
Inverters will be rated by a wattage value, telling you how many watts they can run at one time. For example, imagine you had a 500 Watt Fridge and 800 Watt Air Conditioning. These two items would be 1300 Watts and would require an inverter with a higher wattage than 1300W. Renogy 2000W and 3000W inverter will meet your power needs.
2. Check your battery voltage.
The DC voltage rating on the inverter will tell you what battery bank it is compatible with. For example, a 12V battery bank will require an inverter that is compatible with 12V DC input.
3. Size your installation spaces.
What area or space will you set your inverter? Make sure the inverter will fit in the space you have in mind with enough room around it for proper ventilation and no fire hazards.
4. Remote operation is important.
Renogy pure sine inverters come with convenient remote control and DC HOME APP options so that you can operate the unit from afar.
Pure sine wave inverters are a bigger investment, but much more versatile.
a) Output voltage waveform is a pure sine wave with very low harmonic distortion and clean power like utility-supplied electricity.
b) Inductive loads like microwave ovens and motors run faster, quieter, and cooler.
c) Reduces audible and electrical noise in fans, fluorescent lights, audio amplifiers, TV, Game consoles, Fax, and answering machines.
d) Prevents crashes in computers, weird print out, and glitches and noise in monitors.